
The Nabers Q2N Furcation Probe (3-6-9-12) – 3EZ is a double-ended periodontal instrument designed for detecting and assessing furcation involvement in multi-rooted teeth. Its paired curved Q2N working ends feature clearly defined 3-6-9-12 mm color-coded reference markings, supporting tactile exploration and measured evaluation within furcation areas.
The curved working ends provide complementary access from opposing approaches, helping clinicians adapt to furcation entrances without changing instruments. The lightweight 3EZ handle has a textured grip for tactile sensitivity and controlled maneuverability. With a 6.3 in (16.1 cm) overall length, this configuration offers balanced reach for posterior furcation assessment.
This version pairs calibrated Nabers Q2N working ends with the lightweight 3EZ handle. The curved double-ended design supports alternate access approaches, while the 3-6-9-12 mm reference pattern helps clinicians assess and document furcation involvement with a consistent scale.
Choose Your Handle
Choose 1125 – Nabers Q2N Furcation Probe (3-6-9-12) – 3EZ for a lightweight textured handle that supports tactile sensitivity and easy repositioning.
Prefer a fuller grip? Choose the 1125E – Nabers Q2N Furcation Probe (3-6-9-12) – 6EZ with a larger-diameter deeply knurled handle.
KEY FEATURES
- Nabers Q2N furcation pattern – Designed for assessment of furcation areas in multi-rooted teeth
- 3-6-9-12 mm color-coded markings – Provides distinct reference points on both working ends
- Curved furcation working ends – Support controlled adaptation within furcation entrances
- Double-ended configuration – Provides complementary access approaches without changing instruments
- Tactile and measured assessment – Supports detection, evaluation, and documentation of furcation involvement
- Lightweight 3EZ handle – Textured grip supports tactile sensitivity and controlled maneuverability
- 6.3 in (16.1 cm) overall length – Balanced reach for posterior furcation assessment
- Autoclavable and reusable – Designed for repeated clinical sterilization workflows
- Instrument Type: Furcation probe
- Pattern: Nabers Q2N
- Configuration: Double-ended
- Markings: 3-6-9-12 mm on both working ends
- Measurement Range: Up to 12 mm
- Working-End Design: Curved Q2N Nabers furcation probe ends with color-coded reference markings
- Overall Length: 6.3 in (16.1 cm)
- Handle: Lightweight 3EZ handle with textured grip
- Material: Stainless steel
- Sterilization / Reusability: Steam autoclavable and reusable
- Clinical Use: Furcation entrance detection, tactile and measured assessment of furcation involvement, and periodontal evaluation of multi-rooted teeth
Order and get 200 reward points..
Earn points by signing up for our rewards program